Group 34: PANEL DISPLAY
This group defines the content for control panel (operator
keypad) display (centre area) when the control panel is in the
Output mode.
Code Description Range
3401 SIGNAL1 PARAM 100…178
Selects the first parameter (by number) displayed on the control panel.
Definitions in this group define the display content when the control
panel is in the output mode.
Any parameter number in Group 01: OPERATING DATA can be
selected.
Using the following parameters, the display value can be scaled,
converted to convenient units, and/or displayed as a bar graph.
The figure identifies selections made by parameters in this group.
100 =
NOT SELECTED – First parameter not displayed.
101…178 – Displays parameter 0101…0178. If parameter does not
exist, the display shows “n.a.”.
7 A
0 Hz
3.
15.
15.0Hz
AUTO
MENU00:00
V 44%
7 A
0 Hz
0 %44.
3.
15.
15.0Hz
AUTO
MENU00:00
P 3401 (= 137)
P 3408 (= 138)
P 3415 (= 139)
P 3404 P 3405
P 3404