ABB Tina 7A Service Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 62
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
888-282-2123 • www.jokabsafetyna.com
ABB JOKAB SAFETY
4:11
Manufacturer
ABB AB/Jokab Safety, Sweden
Ordering information
see page 4:57
Level of safety
EN ISO 13849-1
EN 62061
IEC/EN 61508-1…7
EN 954-1
PL e, category 4
SIL 3
SIL 3
Category 4
PFH
d
2.74×10-
8
Color
Grey
Weight
220 g
Power supply
Vital, A1-A2
From Vital to sensors/units, B1-B2
24 VDC ±15%
24 VDC
Fuse
An external fuse should be
tted in the supply to A1
3 AT
Max line resistance
at nominal voltage to X1
150 Ohm
Power consumption
DC supply, nominal voltage
(without load)
DC supply, nominal voltage
(with max load)
3 W
48 W
Dynamic safety circuit
T 1
R 1
Output signal
Input signal
Reset input X1
Supply for reset input
Reset current
Minimum contact closure
time for reset
+24VDC
30 mA max. (inrush current
300 mA during contact closure)
80 ms
Connection of S1
Even numbers of sensors (Eden + Spot T/R + Tina) require a
connection between B1 and S1. S1 is not connected for odd numbers
of sensors. Odd number, no connection between B1 and S1
Number of sensors
Max. number of Eden/Tina to
Vital 1
Total max. cable length to
Eden/Tina
Max. number of Spot T/R to Vital
Total max. cable length to
Spot T/R
30
1000 m
6 pairs
600 m
Maximum number of units varies depending on the installation and
cable size. For more information, see the examples in this chapter
Response time
At Power on
When activating (input-output)
When deactivating (input-output)
At Power loss
< 65 ms
< 40 ms
< 38 ms
< 45 ms
Relay outputs
NO
Max switching capacity,
resistive load
Minimum load
Contact material
Mechanical life
External fuse (EN 60947-5-1)
2
6A/250 VAC/1500 VA/150W
10 mA/10V
AgCdO
>10
7
operations
6.3A or 4A slow
Relay information output
(changeover contact)
Y14 (0V)
+(24V)
Max. load on Y14
Indicates Vital is not reset
Indicates Vital is reset
200 mA (Internal automatic fuse)
LED indication
On
T
R
1
2
Fixed light: supply voltage OK,
Flashing light: under-voltage or
overload
T: Signal out OK. R: Signal in OK.
Indicates that the output relays
have been activated
Mounting
DIN rail
Operating temperature range
35 mm DIN rail
-10°C to + 55°C
Connection blocks (detachable)
Max screw torque
Max connection area:
Solid conductors
Conductor with socket contact
Air and creep distance
1 Nm
1x4 mm
2
/2x1.5 mm
2
/12AWG
1x2.5 mm
2
/2x1 mm
2
4kV/2 DIN VDE 0110
Protection class
Enclosure
Connection blocks
IP 40 IEC 60529
IP 20 IEC 60529
Conformity
EN ISO 12100-1,
EN ISO 12100-2,
EN 954-1,
EN ISO 13849-1,
EN 62061,
EN 60204-1,
IEC 60664-1,
EN 61000-6-2,
EN 61000-6-4
EN 60947-5-1,
EN 1088,
EN 61496-1,
IEC/EN 61508-1…7
Vital 1 Technical Data