888-282-2123 • www.jokabsafetyna.com
ABB JOKAB SAFETY
4:24
Manufacturer
ABB AB/Jokab Safety, Sweden
Ordering information
see page 4:57
Level of safety
IEC/EN 61508-1…7
EN 62061
EN ISO 13849-1
EN 954-1
SIL3
SIL3
PL e, category 4
Category 4
PFH
d
4.50×10
-9
Power supply
Operating voltage
Total current consumption
Time delay t (in/out)
Voltage supply at normal
operation (protection OK) and
24 VDC supply voltage
24 VDC + +15%, -25%
17 mA (27 mA with max
information output)
Information output: Max 10 mA
t < 60 µs
Dynamic input: between
9 and 13 volt (RMS)
Dynamic output: between
9 and 13 volt (RMS)
Information output: ~ 23 VDC
Protection class
IP67
Ambient temperature
Storage: -30…+70°C
Operation: -10…+55°C
Humidity range
35 to 85 %
(with no icing or condensation)
Housing material
Based on polyamide,
Macromelt OM646 (V0)
Connector
M12 5-pole male
Size
48 × 23 × 15 mm (L x W x H)
Weight
~20 g
Color
Black
Approved standards
European Machinery Directive
2006/42/EC
EN ISO 12100-1:2003
EN ISO 12100-2:2003
EN 60204-1:2007
EN 954-1:1996
EN ISO 13849-1:2008
EN 62061:2005
Certificates V Nord
47
32
24. 5
11. 2
LED
1
2
3
4
5
5-pin M12 male contact
+24 VDC
Dynamic input signal
0 VDC
Dynamic output signal
Not used
Tina 1A Blanking Plug
for Connection Block
Tina 1A is a device that is designed for use with the
connection blocks Tina 4A or Tina 8A where it is
used as a blind plug in unused M12 connections. The
device is tted with a LED for status indication of the
dynamic safety circuit.
Application
Used as a blanking plug in unused
M12 connectors at connection blocks
Features
Indication of status by LED
Approvals
TÜV Nord
Tina 1A Technical Data