888-282-2123 • www.jokabsafetyna.com
ABB JOKAB SAFETY
4:26
Manufacturer
ABB AB/Jokab Safety, Sweden
Ordering information
see page 4:57
Level of safety
IEC/EN 61508-1…7
EN 62061
EN ISO 13849-1
EN 954-1
SIL3
SIL3
PL e, category 4
Category 4
PFH
d
4.50×10
-9
Power supply
Operating voltage
Total current consumption
Time delay t (in/out)
Current through
safety device contacts
Short circuit current
between contacts
Voltage supply at normal
operation (protection OK) and
24 VDC supply voltage
24 VDC + +15%, -25%
47 mA (57 mA with max
information output)
Information output: Max 10 mA
t < 70 µs
12 mA
10 mA
Dynamic input: between
9 and 13 volt (RMS)
Dynamic output: between
9 and 13 volt (RMS)
Information output: ~ 23 VDC
Protection class
IP67
Ambient temperature
Storage: -30…+70°C
Operation: -10…+55°C
Humidity range
35 to 85 %
(with no icing or condensation)
Housing material
Based on polyamide, Macromelt
OM646 (V0)
Connectors
M12 5-pole connector
Green loop wires (A1 & A2)
Orange loop wires (B1 & B2)
Brown (+24 VDC), Blue (0 VDC)
wires (Tina 3Aps only)
Size
54 × 24 × 24 mm (L x W x H)
Weight
~30 g
Color
Black
Approved standards
European Machinery Directive
2006/42/EC
EN ISO 12100-1:2003
EN ISO 12100-2:2003
EN 60204-1:2007
EN 954-1:1996
EN ISO 13849-1:2008
EN 62061:2005
Certificates V Nord
5-pin M12 male contact
+24 VDC
Dynamic input signal
0 VDC
Dynamic output signal
Not used
Cable connection
Safety circuit A1-A2
Safety circuit A1-A2
Safety circuit B1-B2
Safety circuit B1-B2
Brown: +24 VDC
(only Tina 3 Aps)
Blue: 0 VDC
(only Tina 3Aps)
11. 2
24
26.5
36. 3
47.1
56.1
LED × 2
M12
M20×1.5
1
2
3
4
5
1
2
3
4
11. 2
24
26.5
36. 3
47.1
56.1
LED × 2
M12
M20×1.5
1
2
3
4
5
1
2
3
4
11,2
24
LED × 2
5
6
1
2
3
4
1
2
3
4
5
26,5
47,1
36,3
56,1
M12
M20×1,5
Tina 3
Aps
Tina 3A/Aps
Adaptation Unit
Tina 3A/Aps is a device that adapts the safety sensors
with mechanical positive forced disconnecting
contacts, such as emergency stops, switches
and light curtains/light grids, with their own
relay outputs to the dynamic safety loop.
Both Tina 3A and Tina 3Aps are tted with
M20 contacts which simplies connection to safety
sensors prepared for M20 connection. The devices
are then easily connected to the dynamic safety loop
through a 5-pin M12 contact to the Tina device. Tina
3Aps has an extra conductor for the supply voltage to
the safety sensor.
Applications
Adaptation of mechanical positive
forced disconnecting contacts to the dy-
namic safety circuit
Example: emergency stops,
switches, light beams/light curtains
with relay outputs
Features
Simplies the system as well as
maintaining the safety level
Indication of status by LED
Approvals
TÜV Nord
Tina 3A/3Aps Technical Data